This makes no sense because it should always be exclusive.
Also RDB checks it self.
LVM has not possibility to use lvchange.
DRBD is this feature not implemented.
It is better to check if a VM is running in QemuServer then in Storage.
for the Storage there is no difference if it is running or not.
Signed-off-by: Wolfgang Link <w.link@proxmox.com>
add method volume_rollback_is_possible and redactor
Improve error handling
If snapshot is not reversible catch it before vm will lock and shutdown.
This is the case if zfs has an younger snapshot.
Signed-off-by: Wolfgang Link <w.link@proxmox.com>
example of storage.cfg
zfs: omnios
blocksize 8k
target iqn.2010-09.org.openindiana:target1
pool pool1
iscsiprovider comstar
portal 192.168.0.1
sudo 1 (optionnal)
content images
note for fast ssh login:
on solaris host :
/etc/ssh/sshd_config
LookupClientHostnames no
VerifyReverseMapping no
GSSAPIAuthentication no
note for nexenta:
rm /root/.bash_profile
to avoid to go in nmc console by default
Signed-off-by: Michael Rasmussen <mir@datanom.net>
Signed-off-by: Alexandre Derumier <aderumier@odiso.com>
If a plugin overwrites method path() to return optimized setting for qemu,
it can now still use the generic methods from PVE::Storage::Plugin which works
on file system paths (for example the glusterfs plugin).
This is an iplementation for file base storage types.
changes compared to patches from Alexandre:
* use correct locking
* private find_free_diskname() with bug fixes
* changed names of new methods
* always refer to base volumes in volume names
Example volume names:
local:6000/base-6000-disk-9.raw
local:6000/base-6000-disk-9.raw/7000/vm-7000-disk-9.qcow2
local:6000/base-6000-disk-9.raw/7000/base-7000-disk-10.qcow2
this add qemu-img resize for file devices (raw - qcow2) if vm is offline.
otherwise we need to use online qmp block_resize
Signed-off-by: Alexandre Derumier <aderumier@odiso.com>
Currently, if a storage have an infinite timeout (nfs hard option or iscsi with high timeout for failover),
and if the storage is down or is doing ha failover with dual controller
- pvestatd hang on storage_info. (So pve-manager see the host as down, and hang on differents parts, gui,rrds display)
- pvedaemon hang on differents place (storage disk list,vm_status, hardware info,...)
- I also see a lot of qemu-img info process hanging in uninterruptible sleep state with iscsi storage.
This patch add a check to see if the storage is accessible.
For nfs and iscsi : ping with a timeout of 2 second. (Maybe this can be polish with some kind of filesystem/storage read test with timeout...)
Default for other storage plugins is to check nothing. (not a problem with sheepdog,ceph,libiscsi... as commands have timeout)
Signed-off-by: Alexandre Derumier <aderumier@odiso.com>