Update node restrictions to reflect that the storage is not available
anymore on the particular node. If the storage was only configured for
that node, remove it altogether.
Signed-off-by: Fabian Ebner <f.ebner@proxmox.com>
slight style fixup
Signed-off-by: Fabian Grünbichler <f.gruenbichler@proxmox.com>
For ZFS and directory storages, clean up the whole disk when the
layout is as usual to avoid left-overs.
Signed-off-by: Fabian Ebner <f.ebner@proxmox.com>
to avoid duplication. Current callers pass along at least one device,
but anticipate future callers that might call with the empty list. Do
nothing in that case, rather than triggering everything.
Signed-off-by: Fabian Ebner <f.ebner@proxmox.com>
The calls for directory and ZFS need slight adaptations. Except for
those, the only thing that needs to be done is support partitions in
the disk_is_used helper.
Signed-off-by: Fabian Ebner <f.ebner@proxmox.com>
There is a udev bug [0] which can ultimately lead to the udev database
for certain devices not being actively updated. Determining whether a
disk is used or not in get_disks() (in part) relies upon lsblk, which
queries the udev database. Ensure the information is updated by
manually calling 'udevadm trigger' for the changed devices.
It's most important for the 'directory' API path, as mounting depends
on the '/dev/disk/by-uuid'-symlink to be generated.
[0]: https://github.com/systemd/systemd/issues/18525
Signed-off-by: Fabian Ebner <f.ebner@proxmox.com>
Because then it might not be unused anymore. If there really is a
race, this prevents e.g. sgdisk creating a partition on a device
already in use by LVM or LVM destroying a partitioned device.
For ZFS, also get the latest udev info once inside the worker.
Signed-off-by: Fabian Ebner <f.ebner@proxmox.com>
Previously, top-level vdevs like log or special were wrongly added as
children of the previous outer vdev instead of the root.
Fix it by also showing the vdev with the same name as the pool and
start counting from level 1 (the pool itself serves as the root and
should be the only one with level 0). This results in the same kind
of structure as in PBS and (except for the root) zpool status itself.
Signed-off-by: Fabian Ebner <f.ebner@proxmox.com>
When creating a new ZFS storage, also instantiate an import-unit for the pool.
This should help mitigate the case where some pools don't get imported during
boot, because they are not listed in an existing zpool.cache file.
This patch needs the corresponding addition of 'zfs-import@.service' in
the zfsonlinux repository.
Suggested-by: Fabian Grünbichler <f.gruenbichler@proxmox.com>
Signed-off-by: Stoiko Ivanov <s.ivanov@proxmox.com>
when compiling the disk list add a property with a stable
/dev/disk/by-id/ path for a block device when available.
This is needed to create zpools with the stable by-id links
The /dev/disk/by-id/ directory can contain multiple links to the same device
(e.g. when it's used as a LVM PV, or one for the wwn/nvme-eui in addition
to the one with vendor and serial). We take the first one which matches
the bus where the disk is attached. For nvme disks we exclude the one
containing the nvme-eui.
The patch assumes that not all disks need to have such a link (e.g.
virtio-block devices as we pass them to guests).
Additionally the tests were adapted to run successfully.
Signed-off-by: Stoiko Ivanov <s.ivanov@proxmox.com>
Letting LVM set the meta-data size internally was not a good idea, as
it produces really small metadata LVs. Adapts the same logic as the
installer.
Signed-off-by: Tim Marx <t.marx@proxmox.com>
Reviewed-By: Dominik Csapak <d.csapak@proxmox.com>
Tested-By: Dominik Csapak <d.csapak@proxmox.com>
we only allow '-' '_' and '.' int storage-ids and names,
and we do not need to escape '_' and '.' (see man 5 systemd.unit)
Signed-off-by: Dominik Csapak <d.csapak@proxmox.com>
to have a clear method name for this. check_XYZ suggests also that we
return true if the check was OK, but we don't.
Signed-off-by: Thomas Lamprecht <t.lamprecht@proxmox.com>
the syntax for creating a pool with a single disk is
not the same as for mirror, so let the user select it
explicitely
Signed-off-by: Dominik Csapak <d.csapak@proxmox.com>
creates/lists systemd mount units for /mnt/pve/.*
filetypes allowed are ext4 and xfs for now
mount with /dev/disk/by-uuid
Signed-off-by: Dominik Csapak <d.csapak@proxmox.com>
like the LVM API, but return an array for the list,
because we do not have nested data here
and create a vg and thin lv with the name given and use the full size
Signed-off-by: Dominik Csapak <d.csapak@proxmox.com>