Files
pve-storage/test/disk_tests/sas/sda_smart_expected.json
Dominik Csapak 2c048efdaf Diskmanage: extend wearout detection for SAS disk
for some controllers/disks there the line is
Percentage used endurance indicator: x%

so extend the regex for that possibilty.
We even had a test-case for SAS but did not notice we could extract
that info from there...

Signed-off-by: Dominik Csapak <d.csapak@proxmox.com>
2020-12-15 14:42:16 +01:00

7 lines
675 B
JSON

{
"health" : "OK",
"text" : "\nPercentage used endurance indicator: 0%\nCurrent Drive Temperature: 20 C\nDrive Trip Temperature: 70 C\n\nManufactured in week 47 of year 2012\nSpecified cycle count over device lifetime: 0\nAccumulated start-stop cycles: 0\nSpecified load-unload count over device lifetime: 0\nAccumulated load-unload cycles: 0\nElements in grown defect list: 0\n\nVendor (Seagate) cache information\n Blocks sent to initiator = 1286675833552896\n\nVendor (Seagate/Hitachi) factory information\n number of hours powered up = 7127.12\n number of minutes until next internal SMART test = 0\n",
"type" : "text",
"wearout": 100
}